Common Danfoss Controller Display Alarms

1. “CON” Alarm:
  • This is a condenser alarm.
  • This will be displayed when the condenser is not getting enough airflow over it.
  • Possible reasons as to what the cause for this is:
  • Condenser is blocked.
  • Condenser fan motor is not working or is stuck.
  • High ambient temperatures of +45°C.
  • There is an obstruction in front of the grill of the cabinet.

 

2. “ULO” Alarm:
  • This is a low voltage alarm.
  • This will be displayed when the incoming voltage to the cabinet is lower than 195V.
  • The cabinet will cut to the voltage protection, to help protect the cabinet from any damages.
  • Possible reasons as to what the cause for this is:
  • Cabinet is plugged into a multiplug or via an extension cable.
  • Cabinets is being powered by a generator.
  • Eskom are working on the power in the area.
 
3. “DOR” Alarm:
  • This is a door alarm.
  • This will be displayed when the cabinets door has been left open for more than one minute.
  • Possible reasons as to what the cause for this is:
  • Cabinet door is not closing fully.
  • The door sensor is faulty or not making the necessary contact.
  • The door sensor has been damaged or is faulty.

 

4. “E01/02/03” Alarm:
  • This is a sensor alarm.
  • This will be displayed when the controller cannot make contact with one of the probes.
  • The controller will display either “E01”, “E02” or “E03”.
  • Possible reasons as to what the cause for this is:
  • The probe has disconnected from the controller.
  • The probe is faulty, been cut or damaged.
Should you need any assistance, feel free to contact us.
Contact Us

Office Tel: 086 111 3804
Alternative Tel: 011 708 7548 / 0502
Email: stedon@maxicoolsa.co.za

Location

Unit 28, Kya Sands Industrial Village, 22 Elsecar Street,
Kya Sands, 2169,
Randburg,
South Africa

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top